Reported chemical assay
25TK0562A: 14.95 % Ni
Talon Metals Corp. reported 14.95 % Ni over 26.22 metres downhole at Tamarack Nickel-Copper-Cobalt Project, Vault Zone, Minnesota on Sep 9, 2026.
Source checked Sep 10, 2026. Original issuer disclosure ↗ · TLO.TO company record ↗
Included subinterval. This result lies within a reported parent interval. Do not add it to that parent. Where source endpoints are absent, their positions are not invented.
| Field | Reported value | Evidence |
|---|---|---|
| Hole identifier | 25TK0562A | Issuer disclosure ↗ |
| Project as reported | Tamarack Nickel-Copper-Cobalt Project, Vault Zone, Minnesota | Issuer disclosure ↗ |
| Publication date | Sep 9, 2026 | Issuer disclosure ↗ |
| From, downhole (m) | 758.00 | Issuer disclosure ↗ |
| To, downhole (m) | 784.22 | Issuer disclosure ↗ |
| Reported downhole interval (m) | 26.22 | Issuer disclosure ↗ |
| Reported assay grade | 14.95 % Ni | Issuer disclosure ↗ |
| Measurement type | Chemical assay | Issuer disclosure ↗ |
| True-width context | Issuer states these are drill intersections, not necessarily true widths, and that true widths cannot be consistently calculated because the mineralized zones have irregular shapes. | Issuer disclosure ↗ |
| Laboratory named by source | ALS Minerals; the issuer states the laboratory is independent of Talon. | Issuer disclosure ↗ |
| Source location | Table 1, including interval row; Highlights | Issuer disclosure ↗ |
Transparent arithmetic
The reported 14.95 % converts to 149,500 ppm of the same analyte on a mass basis. The grade-length product is 391.989 %·m.
| Calculation | Working | Basis |
|---|---|---|
| Concentration in ppm | 14.95 × 10,000 = 149,500 ppm Ni | Mass-unit conversion |
| Grade × downhole length | 14.95 × 26.22 = 391.989 %·m | Source inputs ↗ |
These calculations are not new assays, true-width estimates, contained metal or an economic comparison. The analyte remains Ni. No interval has been added to an overlapping parent or sibling.
Aggregation and geometry
Table 1 identifies selected assay intervals; no additional cutoff or internal-dilution rule is asserted in this register. Issuer states these are drill intersections, not necessarily true widths, and that true widths cannot be consistently calculated because the mineralized zones have irregular shapes.
Source and coverage
The issuer-reported 46.43 m parent interval and its 26.22 m included interval in drill hole 25TK0562A are recorded here as nickel assays. Other metal grades remain in the original disclosure. Manual transcription checked against linked issuer disclosures. MineralPulse has not independently sampled or assayed the core.
Read the full disclosure and its technical context ↗
Browse the assay register ↗ · How to read the result ↗ · Flag a correction ↗